PERBANDINGAN DAYA DUKUNG AKSIAL PONDASI TIANG BOR TUNGGAL MENGGUNAKAN DATA STANDARD PENETRATION TEST (SPT) DAN PILE DRIVING ANALIZER (PDA) TEST PADA PROYEK PEMBANGUNAN JALAN TOL PANDAAN MALANG

Nur Latifah Khomsiati, I Wayan Jirna, Eko Setyawan

Abstract


Abstrak: Hasil hitungan daya dukung pondasi tiang yang didasarkan pada teori mekanika tanah, sebaiknya perlu dicek dengan mengadakan pengujian tiang untuk meyakinkan hasilnya. Salah satu pengujian tiang yang dilakukan adalah Pile Driving Analyzer (PDA) Test. Penelitian ini membandingkan nilai daya dukung SPT menggunakan 3 metode yaitu Metode Meyerhof, Poulos Davis, dan Luciano Decourt dengan hasil daya dukung PDA Test serta mengetahui rumus perhitungan daya dukung SPT yang paling mendekati hasil PDA Test. Nilai daya dukung ultimit (Qu) pondasi tiang bor tunggal yang dihitung dengan Metode Meyerhof dan Luciano Decourt menggunakan data SPT sudah mendekati nilai daya dukung PDA Test. Sehingga daya dukung SPT dikatakan mampu memprediksi daya dukung pondasi dengan baik Sedangkan metode Poulos Davis hasilnya jauh dari metode lainnya karena tidak memperhitungkan koreksi nilai N-SPT. Nilai daya dukung hasil PDA relatif lebih besar dikarenakan itu pada saat pelaksanaan pengeboran tiang, bentuk dinding tiangnya tidak seragam sehingga luas ujung tiang dan selimut tiang bertambah dan menyebabkan daya dukung menjadi lebih besar. Metode yang paling mendekati hasil Qu PDA adalah Metode Meyerhof, terbukti ada tiga titik yang selisih nilai daya dukungnya kecil. Hal ini dikarenakan pada Metode Meyerhof dilakukan koreksi pada nilai N-SPT.

Kata-kata kunci: Daya Dukung Tiang Bor, Daya Dukung SPT, Daya Dukung PDA Test.

Abstract: Bearing capacity of pile foundation based on soil mechanics theory, should be checked by conducting pole test to assure the result. One of the pole tests performed is the Pile Driving Analyzer (PDA) Test. This study compares the value of SPT support capacity using 3 methods, Meyerhof Method, Poulos Davis, and Luciano Decourt with the result of PDA Test bearing capacity and know the formula of calculation of SPT bearing capacity closest to PDA Test result. The value of bearing capacity (Qu) of single mast pile foundation computed by the Meyerhoff and Luciano Decourt Methods using SPT data is close to the bearing capacity of the PDA Test. So SPT bearing capacity is to be able to predict the bearing capacity of the foundation well. While the Poulos Davis method is far from other methods because it does not take into account the correction of N-SPT value. The value of the bearing capacity of the PDA results is relatively greater because of the time of drilling the pile, the shape of the pile wall is not uniform so that the pole end and the shaft of the pole increases and causes the bearing capacity becomes larger. The method that most closely approximates Qu PDA is Meyerhof Method, there are three points where the difference of the small bearing capacity value. This is because the Meyerhof Method corrected the N-SPT value.

Keywords: Bored Pile Bearing Capacity, SPT Bearing Capacity, PDA Test .


Full Text:

PDF


DOI: http://dx.doi.org/10.17977/um071v24i12019p%25p

Refbacks

  • There are currently no refbacks.




Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

View My Stats